Relative Humidity and Ambient Temp.

The air temperature and humidity of your plot. And everything that can be calculated from them.

Request advice today.
Plantae’s Relative Humidity and Ambient Temperature Sensor continuously measures air conditions in your own farm. From these two data points, the system automatically calculates five key agronomic indicators: thermal integral, chill hours, VPD, dew point and leaf wetness.

Technical specifications

Technical specifications of the Plantae® RH and Ambient T Sensor

ParameterValueDetail
ModelFS400-SHT30Sensirion SHT30 sensor with DAVIS IP65 housing
TransmissionLoRa RFUp to 500 m to the Hub/Receiver/Station
Reading frequencyConfigurableFrom every 2 minutes to every hour
Temperature−40 °C to +125 °CAccuracy ±0.3 °C · Resolution 0.1 °C
Relative humidity0–100 % RHAccuracy ±2 % RH · Resolution 0.1 % RH
ProtectionIP65DAVIS housing resistant to extreme conditions
Housing materialStainless steel + UV ABS plasticCE / RoHS certification
Weight115.8 gLightweight and robust for field installation
Automatic calculations5 indicatorsTI, CH, VPD, Dew Point, Leaf wetness
Model
FS400-SHT30
Sensirion SHT30 sensor with DAVIS IP65 housing
Transmission
LoRa RF
Up to 500 m to the Hub/Receiver/Station
Reading frequency
Configurable
From every 2 minutes to every hour
Temperature
−40 °C to +125 °C
Accuracy ±0.3 °C · Resolution 0.1 °C
Relative humidity
0–100 % RH
Accuracy ±2 % RH · Resolution 0.1 % RH
Protection
IP65
DAVIS housing resistant to extreme conditions
Housing material
Stainless steel + UV ABS plastic
CE / RoHS certification
Weight
115.8 g
Lightweight and robust for field installation
Automatic calculations
5 indicators
TI, CH, VPD, Dew Point, Leaf wetness
How does it work?

One sensor. Two direct measurements. Five agronomic indicators calculated.

01

Field installation
The sensor is installed in the field at approximately 1 meter above the ground, protected by the DAVIS housing that guarantees precise readings without interference from reflected heat. It does not require wiring and transmits the data via LoRa to the receiving Hub.

02

Continuous measurement of temperature and relative humidity
The sensor takes air temperature and relative humidity readings at the configured frequency. These two data points are the basis of all the agronomic calculations that the system performs automatically.

03

Automatic calculation of indicators
Based on the temperature and relative humidity readings, Plantae Manager automatically and continuously calculates the five agronomic indicators: thermal integral, chill hours, VPD, dew point and leaf wetness. No manual calculation or additional sensors are required.
Plantae Manager

All the climatic data from your farm, in a single dashboard.

The sensor data and all calculated indicators are displayed in real time in Plantae Manager. You can:

  • See the evolution of temperature and relative humidity in a continuous graph.
  • Check the accumulated thermal integral and chill hours from the start of the season.
  • View VPD and dew point in real time to assess condensation risk.
  • Check the accumulated leaf wetness hours per day to anticipate fungal diseases.
  • Configure alerts for any temperature or humidity threshold.
  • Access from PC, tablet or smartphone.

Know the real climate of your farm. Not that of the region.

Tell us about your crop and location. We help you assess which configuration you need.

Use cases

For any farm where climate conditions drive agronomic decisions.

Crop phenological monitoring
The thermal integral accumulated from the start of the cycle allows you to estimate with fairly good accuracy when the crop will reach flowering, fruit set, veraison or ripening. This makes it easier to plan treatments, pruning and irrigation further in advance.

Pest and disease prevention
Leaf wetness hours and dew point are the variables most directly related to fungal infection risk. With this real-time data you can identify risk windows and treat at the most effective moment.

Chill hours control in fruit trees
In peach, cherry, almond, apple and other fruit species that require chill hours to flower properly, the sensor keeps an automatic count from the start of winter. This allows you to anticipate whether the season will have a chill deficit and its consequences on production.

Irrigation management by evapotranspiration
Air temperature and relative humidity are the main variables to calculate potential evapotranspiration (PET). With real data from your plot, the PET calculation is much more accurate than with data from external stations, which allows you to adjust irrigation more efficiently.

Automatically calculated metrics

Five agronomic indicators from a single sensor.

The relative humidity and ambient temperature sensor is the basis for automatically calculating five agronomic indicators in Plantae Manager. None of them requires installing additional sensors.

1. Thermal Integral (TI)
Thermal integral is the accumulation of temperature above a base threshold from the start of the crop cycle. It is measured in degree-days. Each crop needs to accumulate a certain amount of heat to move from one phenological stage to the next.
What it is used for: predicting when the crop will reach flowering, fruit set, veraison or ripening; planning treatments in the correct phenological window; anticipating the harvest date; studying the suitability of varieties in an area.
How Plantae calculates it: it sums the hourly temperature above the crop’s base threshold (10 °C by default, adjustable) and accumulates it day by day from the moment the integral becomes positive. For temperatures above 34 °C the excess is not counted.

2. Chill Hours (CH)
Chill hours are the accumulated time during which air temperature is below certain thresholds in the winter dormancy period. Many fruit trees need a minimum number of chill hours to break dormancy and flower properly in spring.
What it is used for: knowing when the crop exits winter dormancy; planning pruning and other winter tasks; anticipating whether the season will have a chill deficit and what consequences it may have on flowering and production.
How Plantae calculates it: it uses the chill effectiveness table, which assigns a different value to each temperature range (temperatures between 0 and 7 °C have the maximum effect; above 15 °C the effect is negative). This makes the calculation more accurate than simply counting hours below 7 °C.

3. Vapor Pressure Deficit (VPD)
VPD is the difference between the vapor pressure that the air could hold at a given temperature and what it actually holds. It indicates how far the air is from being saturated with water vapor.
What it is used for: a high VPD indicates that the air is dry and the crop is transpiring a lot, which can generate water stress even if the soil has moisture. A low VPD indicates high humidity conditions, favorable for the development of fungal diseases. It is also key for evapotranspiration calculation.
How Plantae calculates it: from temperature and relative humidity, the system continuously calculates VPD in kiloPascals (kPa). No additional sensor is needed.

4. Dew Point
Dew point is the temperature to which the air must be cooled for water vapor to condense as dew or frost. When leaf temperature falls below the dew point, the leaf becomes wet.
What it is used for: anticipating episodes of night dew, which are one of the main risk factors for fungal diseases such as mildew or botrytis. Also useful for predicting radiation frosts on clear nights.
How Plantae calculates it: dew point is calculated hourly from temperature and relative humidity. It does not need an additional sensor. When VPD equals 0, the dew point has been reached.

5. Leaf Wetness
Leaf wetness is the number of hours per day that the crop leaf is wet. It is the most direct indicator of fungal infection risk: most pathogenic fungi need the leaf to be wet for a minimum number of hours to germinate and infect.
What it is used for: identifying days with the highest fungal infection risk; adjusting treatment decisions to the actual risk conditions; reducing the number of unnecessary applications.
How Plantae calculates it: the leaf is considered wet when its estimated temperature (ambient temperature minus 3 °C) is less than or equal to the dew point. The system sums those hours each day and shows the daily and period totals in Plantae Manager.

Other Plantae® sensors and solutions

Conductivity Sensor

Control soil salinity and optimize fertigation.

Surface Temperature Sensor

Anticipate frosts and thermal events

Solution: Knowing the moisture of my soil

For the farmer who wants to understand what is being measured and how to interpret it.

Conductivity Sensor

Control soil salinity and optimize fertigation.​

Temperature Sensor

Anticipate frosts and thermal events ​

Solution: Deciding when and how much to irrigate ​

Irrigation decision-making with real-time data.

Rain Gauge

Actual rainfall in your plot. Liters per square meter per event.

Anemometer

Wind speed and direction.

Solar Radiation Sensor

Radiation received by the crop. Key for photosynthesis and PET.

Detect pests and diseases

How to use climatic data to anticipate phytosanitary problems.

Control crop development

Thermal integral, chill hours and phenology.

FAQs

Frequently asked questions about the RH and Ambient T sensor.

None. Thermal integral, chill hours, VPD, dew point and leaf wetness are automatically calculated from the sensor’s temperature and relative humidity readings. No additional device is needed.
The calculations are continuously updated with each sensor reading. Thermal integral and chill hours are displayed as totals accumulated from the start of the configured period.
No. The base threshold (temperature below which the crop does not accumulate effective heat) varies according to the crop. Plantae uses 10 °C as the default value, but the team can adjust it for each crop and client.
Yes. All data from Plantae sensors go to the same Plantae Manager dashboard, where you can see in an integrated way air temperature, relative humidity, thermal integral, and soil moisture, conductivity and temperature data.
A forecast works with data from stations that may be kilometers away from your farm. The sensor measures the exact conditions in your plot. In microclimates, thermal inversion areas or farms with variable altitude, that difference can be significant.

Contact the team to receive a quote tailored to your farm.